Summary
Pharmacom Pharma Mix 4, manufactured by Pharmacom Labs, underwent independent analysis conducted by SIMEC AG, a trusted ISO-accredited laboratory. The testing aimed to verify the product’s composition, dosing accuracy, and microbiological safety. The sample, with an expiration date of June 2020, was submitted and funded by AnabolicLab.com.
The analysis confirmed the presence of all labeled compounds, though variances were noted for certain esters compared to the label claim. Despite minor deviations, the product met microbiological safety standards with no contamination detected.
Detailed Report
Product Overview
- Manufacturer: Pharmacom Labs
- Product Name: Pharma Mix 4
- Batch Number: Not provided
- Expiration Date: June 2020
- Delivery Method: Injectable
Sample Acquisition and Testing
- Test Report Number: C 67094
- Testing Ordered: 28 February 2018
- Sample Received: 28 February 2018
- Analysis Conducted By: SIMEC AG
- Product Submitted By: AnabolicLab.com
- Analysis Paid For By: AnabolicLab.com
Testing Results
Compound | Specification (Label Claim) | Measured Concentration | Accuracy | Variance | Compliance |
---|---|---|---|---|---|
Testosterone Phenylpropionate | 130 mg/ml | 131.3 mg/ml | 100.99% | +0.99% | Yes |
Testosterone Decanoate | 270 mg/ml | 265.0 mg/ml | 98.15% | -1.85% | Yes |
Nandrolone Phenylpropionate | 70 mg/ml | 73.1 mg/ml | 104.43% | +4.43% | Yes |
Nandrolone Decanoate | 130 mg/ml | 128.3 mg/ml | 98.69% | -1.31% | Yes |
Microbiological Testing | Result | Specification |
---|---|---|
TAMC | <1 KBE/ml | Complies |
TYMC | <1 KBE/ml | Complies |
Evaluation of Independent Testing
The results indicate that Pharmacom Pharma Mix 4 demonstrates good adherence to its label claims, with all compounds showing minimal variances within acceptable limits. The product also passed microbiological testing, confirming its sterility. The consistency in measured concentrations reflects robust manufacturing practices for this batch.
However, the findings apply solely to the tested sample, and further independent testing across multiple batches would enhance confidence in the product’s overall reliability.
Conclusion
The independent analysis of Pharmacom Pharma Mix 4 confirms its high level of dosing accuracy and microbiological safety, with measured concentrations closely aligning with label claims. This batch demonstrates strong quality control and manufacturing standards, contributing positively to the product’s reliability.
Disclaimer
This report is published for educational and harm reduction purposes. It pertains solely to the tested batch and does not generalize to all products under the same name. Manufacturer-funded testing may carry inherent biases, and readers are encouraged to cross-reference these findings with independent third-party analyses for comprehensive evaluation.
Discuss the Pharmacom Labs PHARMA Mix 4 lab test results on the AnabolicLab Forum.
(The following images are photographs of the actual product that was submitted for testing.)